· 中文版  · English  ·E-mail  
 
 
Automated In-car Water Dispenser
H-S-(I-II)(Hippo Standard)
H-P-(I-II)(Hippo Practical)
H-B-(I-II)(Hippo Bubble)
H-E-(I-II) (Hippo Extreme)
Product Components
Install Demo
Installation Instructions
 
> alibaba
 
  · Your location:Home > Product > Automated In-car Water Dispenser  
 
 
   
Name:  H-P-(I-II)(Hippo Practical)
Price:  1780(RMB)
Color:
Click:  362
     
 

-----------------------------------------------------------------------------------------------------------------
Content:

    

Hippo brand intelligent in-car water dispenser is an in-car split-type drinking water installation developed and manufactured by Oriental Hippos (Beijing) Technology Co., Ltd. Adopting the design concept of intelligence and user-friendly operation, based on the principle of safety, sanitation, convenience and practicality, it is specially designed for drivers to meet their demand for hot water on the drive by integrating intelligence, fashion and efficiency. All you need to do is press a button and you can enjoy a cup of steaming hot water..


-----------------------------------------------------------------------------------------------------------------
Function parameters:
●  420 milliliters of water can be heated to 100 degrees Celsius in less than a quarter of an hour at a time;
●Infrared sensor working as a water blocking system, which allows you to operate with just one hand ,without a single drop of water; 
●Under the condition of low voltage, automatically stop the working of water dispenser to ensure the priority of the functioning of the car; 
●The introduction of medical peristaltic pump to avoid the exposure of water to the mechanical parts which may  cause pollution; 
●Water temperature be set at your will, which can not only meet the consumers’ demands for drinking water at different temperatures but also can adapt to different  boiling points caused by the changes of altitude, atmospheric pressure ; 
●When the water dispenser stops working, the water left in the pipe and heating box will be pumped back to the tank to prevent  freezing  in winter , and the breeding of bacteria in summer ;  
-----------------------------------------------------------------------------------------------------------------
Technical parameters:
Power Supply: 12V DC 
             24V DC 
Size: Control box: 105 × 51 × 61 mm 
       Host heated box: 240 × 160 × 73 mm 
Power consumption: heating water consumption 150W, heating can not be ignored 
The maximum heating temperature: 100 ° C 
Tap out the maximum water temperature: ≥ 90 ° C (hot water pipes in the 2 meter length of the case. Such as the hot water pipe is too long, then the water temperature will be reduced.) 
Heating of water each time: ≥ 400ml of hot water
--------------------------------------------------------------------------------------------------------------------------------------------------------------------------
Packing List:
●Controlling box: 1
●Host heating box: 1
●One 3-meters-long water pipe and one 3 meters long air pipe
● One 2.5-meter-long hot water pipe.
●3 m long double-stranded power cord( the fuse wire included)
●Product Manual (the Warranty card included)
●Certificate
●Plastic bags in which the following small accessories can be found:
   A.a suit of belts for the fixation of the tank; 4 self-tapping screws; 2 battery connection pole
   B.silica gel plug: 4l   18.9l 
   C.3 three Water Connections; 2 Pipe Clamp 
●A pair of white gloves.

-----------------------------------------------------------------------------------------------------------------
Installation instructions:
In order to ensure the safety of products, health, recommended by the Eastern Hippo (Beijing) Technology Co., Ltd. and its designated agent is responsible for the installation. 
The first step: the installation of control box: 
1. Determine the installation location, take a cup to try the space from top to bottom, clean the parts to paste. 
2. 10P plug one end of cable to connect the control box at the back. 
3. Stent off 3M adhesive on the seal face fixed after the paste. 
The second step: the installation of the heating box console 
1. Heating box at the host is, under the co-pilot seat in its place. 
2. Level or the level of correction to the placement, and fixed with tape. 
3. Whether or not I check the heat up, have not been covered by foreign bodies. 
The third step: the installation of fixed bucket attachment 
1. Will be fixed bucket of high-strength nylon bandages fixed plate installed in the appropriate location (or the front seat side, after the location). 
2. When the tape can be used to install fixed or 3.5mm drill two holes and the attachment screws bag. Nylon strap to adjust to the appropriate length of the fixed plug卡扣buckets. 
The fourth step: the installation of control cable and power cord 
1. Would be nice to connect the control box on the other side of the control cable and under the dashboard Shun shield through the gap between, along the retaining plate into the front door next to. 
2. To the door below the top slot扣板pipeline or screw fixed to unload, clean dust formation will be the laying of cable, and plug the cable into the seats below, and the F-box heating host interface connected to cable, if too long, you can use a rubber band after folding truss, on the console near the heating box. 
3. The power cord plug of the air control box and the host interface connector; Soon the door will be the power cord to the laying of pipeline trough beneath the dashboard to find the inside with the vehicle in front of the line Unicom hole through the primer to the location of car batteries ; will shun the power cord inside front side fixed with cable ties for the sake of safety, the power cord to avoid car circuit and circuit lap. 
4. To cut the power cord to appropriate length of each wire around the exposed about 5mm; red line for the cathode stripes, black line for the negative provisions; cathode connected with the insurance, the insurance the other end fitted with the negative terminals, respectively, and pliers pressed junction. 
5. To be connected to the battery terminals or the polarization of the terminal on the battery, the red line then positive, then negative black line. 
【Note: Hippo Products 12V or 24V two hours, can only use bottles that match the DC. If the voltage should be used with the equipment voltage does not match, should not cause equipment damage and return. 】 
Fifth step: Install the control box and the host heated silicone tube between the box 
1. To 2-meter-long transparent silicone tube and control box on one end of the silicone envelope and simultaneously remove the plug firmly. 
2. To shun silicone tube column with steering wheel shift guard into the gap between the bottom shield, and control cable with the pipe along the trough of the door following the laying of the heating box next to the host to determine when to resume the installation of the door probably扣板Squeeze the location of water pipes, water cut and back-up connection to connect (to play a supportive role, to avoid blocking water when squeezed water pipes), will be cut to the appropriate location of water pipes, and heating to remove the host of the talk box A water and connect solid silicone envelope. 
Sixth step: Install the host box and the heating of the pipeline between the storage containers 
1. The 3-meter-long silicone tube on one end of the gray and Host B on heating box joints on the silica gel to remove the envelope and connect at the same time. 
2. 3 meters in length will be colorless, transparent silicone tube on one end and the host connector C on the heating box on the envelope at the same time to remove the silica gel and connect. 
3. Silicone tube to the other side of two side-by-side along the direction necessary to lay concealed to avoid the extrusion (extrusion case, silica gel pipe will be cut, water connectorization support), to remove silica gel and water containers on the envelope Frontier silicone joint connection, the attention of silica gel plug water pipes then there is the extension of the lower end of one of the water pipes, then the other end of silicone tracheal. 
Step VII: Installation completed, Unicom test 
1. Check your connection is correct, then the insurance into insurance seat tube. 
2. Sheung Shui to check back often water, then pipe it wrong, or extrusion. 
3. To check the various directives issued keys when the light show synchronized. 
4. Inspection correct, the installation of the door line and restore the original slot. 
5. Regulating the temperature required.  
-----------------------------------------------------------------------------------------------------------------
Help:
Products of the public can provide any type of ambient temperature water temperature or hot water (up to 100 ℃). 
Control box on three touch buttons and indicator 6. (Photos and a detailed description of the key indicator of the function and name) 
Unicom power, the power indicator light Always. In a standby status at this time, very low power. Long time do not use motor vehicles such as when the insurance will be connected to the battery tube removed, so that the total power dispenser. 
Sheung Shui / back water keys: Control, Sheung Shui, water feature back. Press this key, the system beginning in Sheung Shui, water back. Sheung Shui during the top of the screen showing the three red boldface, Sheung Shui after, ℃ lights, lights ambient temperature, between parts of the screen showing that the water temperature in the heating tank; the process of withdrawal of water in the bottom three red boldface, After the retreat of water, and other status light is off, only power lights. 
Heated / ambient temperature keys: water dispenser control job status. Press this key, adjustable ambient temperature to heating or status. Power lights, ℃ lights, related to status lights (heated or ambient temperature) light, the screen display in real-time temperature heating. 
Function / Switch button: adjust the keys to display the temperature of heating water tank, car operating voltage, the surface temperature of the host box (when the show every day for the first time the ambient temperature inside the car), three light conversion, indicating the corresponding state temperature and voltage. 
Ambient temperature for drinking water: 
1. By Sheung Shui / back water key, the system in Sheung Shui, the temperature display shows the heating tank. 
2. Sheung Shui after the buzzer noise to alert can take water. 
3. Insert the control box put the cup out of faucets, drinking water directly. Sense because of the use of infrared light blocking technology, leaving the cup when the faucets, the water will automatically stop. 
4. By Sheung Shui / back water key, start the mandatory retirement system water, such as the water did not take this key, the system will automatically 2 minutes after the withdrawal of water. 
Drinking hot water: 
1. By Sheung Shui / back water key, the system in Sheung Shui, the temperature display shows the heating tank. 
2. By heating / key ambient temperature, heating lights, the system status to enter the heating, the heating process should not take water. For drinking, may again press the heated / ambient temperature button, switch status to the ambient temperature, you can access the water. Such as in Sheung Shui 2 minutes after heating did not select, and display temperature is below 50 ℃, the system will automatically back water, the guarantor, the safety of cars and drinking fountains. 
3. At the water temperature to set temperature, alarm system, automatic heat finished glass can be inserted into the control box then tap water for drinking. 
4. By Sheung Shui / back water key, the system function to start the compulsory retirement of water. Failure to select back the water, when the heating temperature box below to 50 ℃, the system will automatically back water (not to the proposed high-temperature state of compulsory retirement under the water, in order to avoid plastic water containers烫坏). 
When required for drinking water, the need to Sheung Shui heating, may choose to use a shortcut: directly heated / ambient temperature button, the system will automatically Sheung Shui, Sheung Shui, after the heating process automatically. 
【Access to drinking water must not be higher than the tap water in order to avoid a sense of infrared light water submerged receiver failure, resulting in more than water. 】 
-----------------------------------------------------------------------------------------------------------------
Troubleshooting:
First, failure to check: 
A. Products of the public press at the Sheung Shui / back water keys, the indicator light does not shine: 
● check whether fuse intact. 
● right to check whether water dispenser connections: the control box to control the back of the heating cable and host of the connection box is correct. 
● Host check box heating of the power cord and battery connections are correct: red stripes Line cathode, anode Black Line. 
● check whether the normal battery voltage. 
B. Water dispenser at work, between the location of the screen appear three red boldface, and issued a short buzzer sounds: 
● Host heating water containers in the box from serious water shortages. 
● Inspection of water containers on the silica gel plug and the water leakage between the tube. 
● check box to connect the host heating water pipes and storage containers installation is correct, and confirm whether or not to be squeezed, bent or broken. 
● Host heated box below to check whether there is flowing out. If so, should contact the replacement supplier silicone tube vulnerability peristaltic pump head, or contact the Company to guide replacement. 
C. Water, the control box is not flowing out from the Tap: 
● check box to connect the host and control the heating of the silica gel box is the correct installation of water pipes; has been squeezed, bent or broken. 
● check whether the use of transparent or translucent glass, can not be separated by a sense of control of infrared light. 
D. Equipment suddenly stop working, all the light body: 
● check whether the fuse and check the battery in good condition. 
● Battery check box with the host between the heating power cord is bad. 
● If you exclude all the light of the above reasons have yet to restore status, the temperature safety devices are activated. Please contact your supplier, hippo water dispenser license must be approved by the Intelligent Vehicle maintenance professionals. 
E. Access to drinking water, the water flow more. 
● access to drinking water because when water is higher than the tap, water will be infrared receiver submerged sense of failure, resulting in more than water. Stop the use of 1-2 hours, until the infrared light flu Tap dry receiver can continue normal use. 
6, fault code table: 
Fault treatment programs show that the cause of the malfunction 
       E1 temperature sensor fault contact with the supplier 
       E2 battery voltage check the car battery or vehicle power supply system, the drinking fountains in the automotive voltage less than 10V automatic ban on the use of 
       E3 pipe plug to check whether there is water fountain pipe extrusion or bending caused by serious water poor 
       E4 supplier contact leakage 
       E5 exceeded the ambient temperature (-1 ℃) and no ice-melting ice-melting function at this time no do not use the drinking fountains, to be the ambient temperature rose to above 0 ℃ failure alarm automatic discharge 

【TOP】
Copyright © 2009 hippos.com.cn Inc. All Rights Reserved. Oriental hippos (Beijing)Technology CO., Ltd. All rights reserved
Address:Kwong Hing Industrial Development Zone, North Main Street on the 3rd, Daxing, Beijing       TEL:010-87672698    87611373
 E-mail: hema@hippos.com.cn       京ICP备:07006726    You are this website visitor No. 32879